Share
Export Citation
Seismic Performance of Cellular Lightweight Concrete Block Panels as Infilled Wall in RC Frames Due to Cyclic Lateral Loading
Salu Y.L.
Engineering Technology and Applied Science Research
Q2Abstract
Indonesia experiences frequent earthquakes due to its proximity to seismic faults. Many one- or two-story residential buildings with reinforced concrete frames filled with masonry are severely damaged during moderate to high-magnitude earthquakes. One solution to reduce seismic loads on the structures is the use of Cellular Lightweight Concrete (CLC). The behavior of CLC block panels as an infill wall against lateral cyclic loading is the subject of this experimental investigation. The specimens consist of two Reinforced Concrete (RC) frame models: a CLC block panel used as an infill wall for the RC frame (DB-2) and a reinforced concrete frame (DB-1). This research uses displacement control methods and lateral cyclic loading to evaluate the behavior of wall structures according to the ASTM E2126-02a. The results showed that the strength value of the DB-2 specimen was 29.61% higher than that of the DB-1 specimen. Neither loading nor unloading of the DB-2 specimen caused a decrease in relative stiffness, unlike the DB-1 specimen. This indicates that the DB-2 specimen does not experience a squeezing effect and instead becomes more stable and has improved energy dissipation without losing strength. The results show that bricks, concrete blocks, and other fillers can be replaced with precast CLC panels for reinforced concrete frame walls.
Access to Document
10.48084/etasr.8444Other files and links
- Link to publication in Scopus
- Open Access Version Available