# The design and sensitivity of JUNO’s scintillator radiopurity pre-detector OSIRIS
> Abusleme A.
URL kanonis: https://discover.unhas.ac.id/publications/pub_scopus_85118856336
Jurnal / Konferensi: European Physical Journal C
Tahun terbit: 2021
DOI: https://doi.org/10.1140/epjc/s10052-021-09544-4
ISSN: 14346044
Kuartil SJR: Q1
Citations: 31
## Authors
- Abusleme A.
## Abstract
Abstract The OSIRIS detector is a subsystem of the liquid scintillator filling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $$10^{-16}\hbox { g/g}$$ 10 - 16 g/g of $$^{238}\hbox {U}$$ 238 U and $$^{232}\hbox {Th}$$ 232 Th requires a large ( $$\sim 20\,\hbox {m}^3$$ ∼ 20 m 3 ) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.
## Keywords
- Scintillator
- Algorithm
- Physics
- Analytical Chemistry (journal)
- Materials science
- Detector
- Computer science
- Chemistry
- Optics
- Chromatography
---