# Structural ductility of RBS on castellated beam subjected to cyclic loading > Aswad N.H. URL kanonis: https://discover.unhas.ac.id/publications/pub_scopus_85079638490 Jurnal / Konferensi: Iop Conference Series Earth and Environmental Science Tahun terbit: 2020 DOI: https://doi.org/10.1088/1755-1315/419/1/012151 ISSN: 17551307 Citations: 2 ## Authors - Aswad N.H. ## Abstract Abstract RBS placement on a castellated beam on exterior connection structure with RBS position from column face refers to Prequalified Connection for Special and Intermediate Moment Frames for Seismic Application AISC 358-10, Article 5.8. The column beam test aims to evaluate structural ductility of the RBS on the castellated beam flange from the column face. The study was expected to explain the effect on column beam joints to provide input for planning earthquake-resistant building structures. The results show that the castellated test beam with RBS could withstand a load of 12.05 kN with a value of 4.2 structural ductilities. ## Keywords - Flange - Structural engineering - Beam (structure) - Ductility (Earth science) - Materials science - Connection (principal bundle) - Column (typography) - Composite material - Engineering - Creep --- Sumber: Discover Unhas — RIMS Universitas Hasanuddin. Saat mengutip, gunakan DOI bila tersedia atau URL kanonis di atas.