Confinement behavior of spun pile using low amount of spiral reinforcement - An experimental study

Irawan C.

International Journal on Advanced Science Engineering and Information Technology

Q4
Published: 2018Citations: 18

Abstract

In this paper, further analysis from the result of spun pile test under reverse flexural load and combined with two levels constant axial load, 40 tons (0.08fc’Ag) and 80 tons (0.16fc’Ag), is presented. The analysis is related to the confinement behavior of the concrete section of pile using the low amount of spiral reinforcement. It is shown that the strain readings from the spiral reinforcement indicate a subtle contribution in terms of confinement mechanism of the hollow section of a pile. In addition, it is evident that spiral reinforcement seems to be compressed when the concrete section resists compression strain due to flexural load. The crushing of concrete at ultimate condition could also not be resisted by spiral reinforcement by any means.

Access to Document

10.18517/ijaseit.8.2.4343

Other files and links

Fingerprint

ReinforcementSciences
Spiral (railway)Sciences
PileSciences
Structural engineeringSciences
Materials scienceSciences
Flexural strengthSciences
Compression (physics)Sciences
Composite materialSciences
EngineeringSciences
Mechanical engineeringSciences