esc

Type at least two characters to start searching.

↑↓ select↵ openesc close

Share

Export Citation

APA
MLA
Chicago
Harvard
Vancouver
BIBTEX
RIS
Universitas Hasanuddin
Research output:Contribution to journal›Article›peer-review

Utilization of turbidity sensor for detecting precipitate formation in AB nutrient solution as a reference for stirrer activation in a smart hydroponic tank system

Mubarak H.

Iop Conference Series Earth and Environmental Science

Published: 2026

Abstract

In hydroponic systems, a consistent and homogeneous supply of nutrients is crucial for optimal plant growth. However, AB nutrient solutions are prone to precipitation due to chemical imbalances, pH fluctuations, or prolonged storage. These precipitates can reduce nutrient availability, and lead to economic losses. This research presents the design of a device called Smart Tank, which is capable of automatically supplying nutrients and activating a mixing mechanism based on real-time sensor data. The system utilizes a turbidity sensor to detect changes in clarity as an indicator of precipitate formation, while TDS (Total Dissolved Solids) and pH sensors monitor the quality and concentration balance of the nutrient solution. When the turbidity value exceeds a predefined threshold, the mixing system is automatically activated to re-homogenize the solution. Data from the TDS and pH sensors also serve as control parameters to ensure nutrient levels remain within optimal ranges for plant absorption. By integrating these sensors into an automated system, the Smart Tank improves nutrient delivery efficiency, reduces manual intervention, and minimizes the risk of crop failure due to nutrient imbalances or sedimentation. Based on the testing, the turbidity sensor performed as expected, exhibiting a very strong linear relationship between the turbidity values (NTU) and the sensor output voltage, with an R 2 value of 0.9981. The sensor was able to detect the occurrence of precipitation, as indicated by the decrease in NTU readings: Solution A decreased from 4.1036 NTU to 2.528 NTU, and Solution B decreased from 4.9542 NTU to 3.528 NTU. This decline in turbidity values indicates that particles in the nutrient solutions settled at the bottom of the container, demonstrating the sensor’s effectiveness in monitoring the precipitation process.

Other files and links

Fingerprint

TurbiditySciences
NutrientSciences
Environmental scienceSciences
Environmental engineeringSciences
Mixing (physics)Sciences
PrecipitationSciences
HomogeneousSciences
Process engineeringSciences
HydroponicsSciences
AttenuationSciences
Water qualitySciences
Pulp and paper industrySciences
DilutionSciences
ChemistrySciences