Share

Export Citation

APA
MLA
Chicago
Harvard
Vancouver
BIBTEX
RIS
Universitas Hasanuddin
Research output:Contribution to journalArticlepeer-review

Modified Implant Fixation Technique Is an Alternative for Patients with an Anterior Cruciate Ligament Tear in Limited Resource Settings: A Comparison Functional Outcome Study with Polyether Ether Ketone and Bioabsorbable Screws

Sakti M.

Journal of Clinical Medicine

Q1
Published: 2024Citations: 1

Abstract

<b>Background:</b> Anterior cruciate ligament (ACL) injury is one of the most prevalent factors contributing to knee instability worldwide. This study aimed to evaluate modified metal fixation techniques for ACL reconstruction compared to factory-made implants, such as polyether ether ketone (PEEK) screws, bioabsorbable screws, and modified metal implants. <b>Methods:</b> A retrospective cohort analysis was conducted to assess the functional outcomes of ACL using various fixation methods. Patients who underwent arthroscopic ACL reconstruction at several healthcare facilities were included in the study. The functional outcomes were evaluated using the Lysholm Knee Scoring Scale and the International Knee Documentation Committee (IKDC) score questionnaire at 6- and 12 months post-surgery. Statistical analyses, including the Shapiro-Wilk test and analysis of variance, were performed to compare outcomes among the fixation groups. <b>Results:</b> Thirty-three patients who underwent ACL reconstruction surgery with varying distributions across the three fixation groups (modified metal implants, PEEK screws, and bioabsorbable screws) were included in the study. As measured by the Lysholm and IKDC scores at 6- and 12 months post-surgery, the PEEK group demonstrated the highest average scores. Nevertheless, these functional outcomes were not significantly different between the groups (<i>p</i> = 0.140, 0.770, 0.150, and 0.200). These findings align with those of meta-analyses comparing different fixation methods for ACL reconstruction. <b>Conclusions:</b> While acknowledging the small sample size as a limitation, this study suggests that modified metal implants represent viable options for ACL reconstruction. The selection of fixation methods should consider patient characteristics and preferences, emphasizing biomechanical stability and long-term outcomes. Further research is needed to validate these findings and explore their biomechanical properties and cost-effectiveness.

Access to Document

10.3390/jcm13102964

Other files and links

Fingerprint

MedicineSciences
Anterior cruciate ligamentSciences
Fixation (population genetics)Sciences
ImplantSciences
Polyether ether ketoneSciences
Anterior cruciate ligament reconstructionSciences
SurgerySciences
OrthodonticsSciences
PeekSciences
PopulationSciences
Environmental healthSciences
ChemistrySciences
Organic chemistrySciences
PolymerSciences