Share

Export Citation

APA
MLA
Chicago
Harvard
Vancouver
BIBTEX
RIS
Universitas Hasanuddin
Research output:Contribution to journalArticlepeer-review

Mechanical behavior of the U-anchor of super-CFRP rod under tensile loading

Djamaluddin R.

Journal of Composite Materials

Q2
Published: 2014Citations: 14

Abstract

A suitable anchoring system is required to anchor a CFRP tendon due to its sensitivity in lateral pressure. Recent developed anchors are still relying on lateral pressure in anchoring CFRP tendons. A new CFRP unit equipped with U-anchor at both end of the rod body without any jointing (namely of Super CFRP, S-CFRP) has been developed. This paper presents the mechanical behavior as well as failure mechanism of U-anchor under direct loading and loaded under embedded within concrete, respectively. The rupture occurred on the circular part of U-anchor under direct loading. The stress concentration on circular loop was the cause of U-anchor rupture. Loading of U-anchor embedded within concrete indicated an optimum capacity. The failure was out of the anchor system. Finite element model of U-anchor embedded within concrete showed better stress distribution on anchor at rupture load such that the stress on U-anchor was lower than CFRP strength.

Access to Document

10.1177/0021998313491514

Other files and links

Fingerprint

AnchoringSciences
Materials scienceSciences
Structural engineeringSciences
Ultimate tensile strengthSciences
Finite element methodSciences
Stress (linguistics)Sciences
Ultimate loadSciences
Composite materialSciences
Anchor boltSciences
Ultimate failureSciences
EngineeringSciences
PhilosophySciences
LinguisticsSciences